You Searched For: Electrophoresis Systems

Capable of running multiple gels simultaneously, the electrophoresis systems separate DNA, RNA, and protein mixtures based on the sizes of molecules. After a uniform charge is directly applied, molecules are pushed through a porous gel at different rates based on size. The equipment was specifically designed to produce bands without smiling for clear conclusion. Available in both vertical and horizontal formats, researchers can modify the gel positioning to meet specific testing requirements.

Capable of running multiple gels simultaneously, the electrophoresis systems separate DNA, RNA, and protein mixtures based on the sizes of molecules. After a uniform charge is directly applied, molecules are pushed through a porous gel at different rates based on size. The equipment was specifically designed to produce bands without smiling for clear conclusion. Available in both vertical and horizontal formats, researchers can modify the gel positioning to meet specific testing requirements.


134  results were found

SearchResultCount:"134"

Sort Results

List View Easy View

Rate These Search Results

Catalog Number: (700-0913)
Supplier: VWR Collection
Description: The Maxi L system can be used to run up to 600 samples, making it perfectly suited for large scale sample screening where up to 12 microtitre combs can be used on the same 23×40 cm gel tray.
UOM: 1 * 1 items


Supplier: VWR Collection
Description: The JustCast system is a flexible and quick system for casting multiple PerfectBlue™ compatible 'mini' gels at the same time, without the need to tape. Adjustable to fit all gel trays featured in the PerfectBlue™ mini gel series, this system comes fitted with an easy to read bubble level and adjustable feet to ensure a level casting of the gel. At any one time, the system can fit three Mini S, two Mini M or two Mini L trays.

New Transparency for European Customers

Have you noticed our new improved visibility on stock location at checkout?

Find out more

Enhancement to stock locations

Catalog Number: (700-0799)
Supplier: VWR Collection
Description: The 'Revolution' series includes a buffer circulation system, powered by the electrodes themselves. Hydrogen bubbles produced at the cathode pass up a diagonally positioned pipe connected to the two sides of the tank producing a gentle circulation of the buffer. The result is no pH and ionic gradient – without need of mechanical pumps.
UOM: 1 * 1 items


Catalog Number: (700-0912)
Supplier: VWR Collection
Description: The Maxi ExW 'Revolution' offers built-in buffer recirculation - without the need for pumps or additional tubing. The Maxi ExW 'Revolution' offers the same high throughput, rapid separation as the Maxi ExW model but, with the position of the cathode and a rising tube, the system uses hydrogen bubbles to slowly mix the buffer. This system thereby avoids the build-up of pH or ionic gradients for electrophoresis of maximum quality and stability.
UOM: 1 * 1 items


Catalog Number: (700-0909)
Supplier: VWR Collection
Description: Based on the Maxi M model, the Maxi M 'Revolution' offers a built-in buffer circulation system, powered by the system’s electrodes. At the cathode, hydrogen bubbles are produced and pass up a diagonally positioned pipe connected to the two sides of the tank to produce a gentle and continual circulation of the buffer. The system nulls any pH and ionic gradient – without the fuss of mechanical pumps. The system offers 6 comb positions enabling the gel to be partitioned into 2, 3 or 4 areas. In addition, the system can accommodate any of the 23 standard and microtitre comb designs described for the Maxi M model.
UOM: 1 * 1 items


Catalog Number: (700-0814)
Supplier: VWR Collection
Description: Capable of rapidly running up to 160 samples, the Midi S is a compact, but highly efficient, electrophoresis system. Versatility is built-in, with six different comb positions and a choice of 10 different comb types and thicknesses available. For rapid handling, special microtitre combs enable rapid loading with a multichannel pipette, while the effective rubber sealed 'end gates' allow gel pouring right in the tray. With its sturdy design and straight electrodes, the results are clear, crisp and quick, free from 'smiling' bands.
UOM: 1 * 1 items


Catalog Number: (700-0777)
Supplier: VWR Collection
Description: Capable of running 12×14 cm gels, the largest of the 'Mini' range still offers the convenience of direct gel casting in the tray, in an easy to manage product size for reliable, high quality electrophoresis. This system can be supplied with a choice of gel trays suitable for 2, 4 or 12 combs, and an expansive range of standard and microtitre combs, making this versatile system appropriate for both routine and small separation electrophoresis.
UOM: 1 * 1 items


Supplier: VWR Collection
Description: Extra wide, for gels 20×10 cm, Twin ExW S is ideally suited to rapid analytical separations or large sample separation. The combination of the triple-cathode construction, and effective cooling provides a stable environment for high quality sample separation.

Catalog Number: (700-0842)
Supplier: VWR Collection
Description: With its extra wide design, the Midi ExW is ideal when there is a need to run lots of samples (up to 200) in just a short distance, for example, when genotyping. This format, along with its compact footprint, offers rapid run times without compromising on power. The result is a system for high throughput sample processing, generating crisp clear band data. As with all PerfectBlue gel systems, gels can be poured directly in the trays at temperatures up to +60 °C. With the Midi ExW, the trays can be walled with effective gasketed 'end gates' which are supplied in the system. In addition, gel size can be reduced by using wall combs or the aluminium casting dam.
UOM: 1 * 1 items


Supplier: VWR Collection
Description: VWR® Real Time electrophoresis systems have revolutionised DNA electrophoresis. it is no longer necessary to remove a gel from a tank, place it onto a transilluminator for viewing or place the gel into an imaging system to take a photo. These versatile and compact systems are an all-in-one replacement for a power supply, gel tank, transilluminator and gel imaging system.

Sale

Supplier: VWR Collection
Description: The largest of the series, the Twin L can accommodate 20×20 cm gels for the simultaneous separation of up to 50 samples making this system ideally suited to either higher throughput or separating lower molecular weight samples. The system actively manages temperature build up with an efficient water cooling system and central aluminium ceramic plates for effective and safe long-term operation.

Supplier: VWR Collection
Description: For 16×14 cm gels, the Twin M is a versatile system for SDS PAGE applications, in addition to non denaturing electrophoresis of proteins, SSCPs and dinucleotide repeats. With the enlarged upper buffer chamber, water circulation system and heat-sinking aluminium ceramic plates, the Twin M provides high speed separation while maintaining straight, sharp bands.

Catalog Number: (700-0876)
Supplier: VWR Collection
Description: The smallest of the Maxi series, the Maxi S Plus is suitable for high quality sample separation of up to 160 samples per run. With this flexible system, the gel size can be split into two, three or four sections by using different comb positions, plus the gel size can be reduced using the wall comb or the casting dam system.
UOM: 1 * 1 items


Catalog Number: (700-0292)
Supplier: VWR Collection
Description: The shiroGEL mini vertical PAGE system is modular, allowing PAGE and electroblotting to be carried out in the same tank, simply by changing the inserts. The system features inserts for each application, and a common buffer tank in which to run them. Each insert has its own electrode assembly, which connects to the lid of the buffer tank. For safety, the power leads connect directly to the lid. When the lid is removed, power is disconnected from the system. The inserts also have a small pad that fits into position in the lid. This ensures that the lid is always properly placed and aids in its removal. The buffer tank is moulded to prevent separation and leaking. A variety of spacers, combs and other accessories are available to customise the system. All spacers and combs are colour coded or clearly labelled to indicate thickness.
UOM: 1 * 1 items


Catalog Number: (700-0880)
Supplier: VWR Collection
Description: Wider than the Maxi S Plus, the Maxi M model can accommodate up to 168 samples but still with an economical footprint.
UOM: 1 * 1 items


Catalog Number: (700-0910)
Supplier: VWR Collection
Description: This 'extra wide' Maxi tank was developed especially for large sample numbers and rapid separation times. Accommodating up to 10 microtitre combs, the Maxi ExW can be used to separate up to 500 samples and facilitates error-free loading with multichannel pipettes. By optimising the position of the embedded platinum electrode and the use of the three-point levelling platform, with in-built bubble level, the Maxi ExW provides highly reproducible and dependable sample separation, free from 'smiling' effects.
UOM: 1 * 1 items


Inquire for Price
Stock for this item is limited, but may be available in a warehouse close to you. Please make sure that you are logged in to the site so that available stock can be displayed. If the call is still displayed and you need assistance, please call us on +353 1 88 22222.
Stock for this item is limited, but may be available in a warehouse close to you. Please make sure that you are logged in to the site so that available stock can be displayed. If the call is still displayed and you need assistance, please call us on +353 1 88 22222.
This product is marked as restricted and can only be purchased by approved Shipping Accounts. If you need further assistance, email VWR Regulatory Department at eurega_services@eu.vwr.com
-Additional Documentation May be needed to purchase this item. A VWR representative will contact you if needed.
This product has been blocked by your organisation. Please contact your purchasing department for more information.
The original product is no longer available. The replacement shown is available.
Product(s) marked with this symbol are discontinued - sold till end of stock. Alternatives may be available by searching with the VWR Catalog Number listed above. If you need further assistance, please call VWR Customer Service on +353 1 8822222.
1 - 16 of 134
no targeter for Bottom