You Searched For: (3-Chloropropyl)trimethoxysilane

Vertical gel electrophoresis systems are primarily used for nucleic acid or protein sequencing. Achieve precise voltage control using this format that forces charged molecules to travel through the casted gel since it is the only buffer chamber connection. The low current used with the vertical gel systems does not require buffer to be recirculated. With strong clamps to guarantee the assembly stays in an upright position, the equipment facilitates fast gel runs with even cooling resulting in distinct bands.

Vertical gel electrophoresis systems are primarily used for nucleic acid or protein sequencing. Achieve precise voltage control using this format that forces charged molecules to travel through the casted gel since it is the only buffer chamber connection. The low current used with the vertical gel systems does not require buffer to be recirculated. With strong clamps to guarantee the assembly stays in an upright position, the equipment facilitates fast gel runs with even cooling resulting in distinct bands.


56 536  results were found

Sort Results

List View Easy View
SearchResultCount:"56536"
Description: Extra wide, for gels 20×10 cm, Twin ExW S is ideally suited to rapid analytical separations or large sample separation. The combination of the triple-cathode construction, and effective cooling provides a stable environment for high quality sample separation.
Catalog Number: 700-0986
UOM: 1 * 1 items
Supplier: VWR Collection


Description: For 16×14 cm gels, the Twin M is a versatile system for SDS PAGE applications, in addition to non denaturing electrophoresis of proteins, SSCPs and dinucleotide repeats. With the enlarged upper buffer chamber, water circulation system and heat-sinking aluminium ceramic plates, the Twin M provides high speed separation while maintaining straight, sharp bands.
Catalog Number: 700-0961
UOM: 1 * 1 items
Supplier: VWR Collection


Description: The largest of the series, the Twin L can accommodate 20×20 cm gels for the simultaneous separation of up to 50 samples making this system ideally suited to either higher throughput or separating lower molecular weight samples. The system actively manages temperature build up with an efficient water cooling system and central aluminium ceramic plates for effective and safe long-term operation.
Catalog Number: 700-1205
UOM: 1 * 1 items
Supplier: VWR Collection


Description: The PerfectBlue Twin S system is designed for rapid separation of typical 10×10 cm mini gels. Due to its small size and a separation capacity of 6 to 30 samples, it is ideal for fast, analytical separations. A highly efficient cooling system ensures uncompromising results.
Catalog Number: 700-0937
UOM: 1 * 1 items
Supplier: VWR Collection


Description: The shiroGEL vertical 20 offers application flexibility and is distinguished by its ease of gel casting and set-up, requiring only four screws to secure up to four 20×20 cm gels. This vertical screw clamp technology distributes pressure evenly along the height of gel rather than in the centre to eliminate plate bowing and gel compression, while maintaining a leakproof seal during casting. A built-in inner buffer chamber within the PAGE insert allows set up to be completed without inclusion of an upper buffer chamber. These systems are ideal for 1D and 2D SDS-PAGE, native, preparative, gradient and high resolution nucleic acid electrophoresis.
Catalog Number: 700-0353
UOM: 1 * 1 items
Supplier: VWR Collection


Description: The shiroGEL mini vertical PAGE system is modular, allowing PAGE and electroblotting to be carried out in the same tank, simply by changing the inserts. The system features inserts for each application, and a common buffer tank in which to run them. Each insert has its own electrode assembly, which connects to the lid of the buffer tank. For safety, the power leads connect directly to the lid. When the lid is removed, power is disconnected from the system. The inserts also have a small pad that fits into position in the lid. This ensures that the lid is always properly placed and aids in its removal. The buffer tank is moulded to prevent separation and leaking. A variety of spacers, combs and other accessories are available to customise the system. All spacers and combs are colour coded or clearly labelled to indicate thickness.
Catalog Number: 700-0292
UOM: 1 * 1 items
Supplier: VWR Collection


Description: Vertical gel electrophoresis system, Dual gel vertical gel electrophoresis, Dual gel, uncooled, Owl P82, 100×80 - 100 mm
Catalog Number: 720-2856
UOM: 1 * 1 items
Supplier: THERMO OWL SCIENTIFIC


Description: The Owl™ P9DS dual gel system is designed for quick and easy casting and running of one or two gels on the same device. When used with the available combs, spacers, alumina plates and glass, this system is an ideal tool for second dimension protocols of 2-D electrophoresis, SDS and agarose gels, and native PAGE electrophoresis.
Catalog Number: 700-2340
UOM: 1 * 1 items
Supplier: THERMO OWL SCIENTIFIC


Description: The SE250 Mighty Small II mini vertical protein electrophoresis unit is designed for quick screening and rapid electrophoretic separation.
Catalog Number: 732-1752
UOM: 1 * 1 items
Supplier: HOEFER ELECTROPHORESIS


Description: Replacement parts for SE600X Chroma™
Catalog Number: 732-1939
UOM: 1 * 2 items
Supplier: HOEFER ELECTROPHORESIS


Description: The SE260 Mighty Small II Deluxe mini vertical electrophoresis unit combines the advantages of small format and efficient cooling for rapid screening of proteins and nucleic acids.
Catalog Number: 732-2598
UOM: 1 * 1 items
Supplier: HOEFER ELECTROPHORESIS


Description: SE300 miniVE™ integrated vertical electrophoresis and blotting unit allows performance of both electrophoresis and electro transfer in one sturdy, compact unit.
Catalog Number: 732-1772
UOM: 1 * 1 items
Supplier: HOEFER ELECTROPHORESIS


Description: Vertical gel electrophoresis system
Catalog Number: 732-1696
UOM: 1 * 1 items
Supplier: HOEFER ELECTROPHORESIS


Description: Vertical gel electrophoresis system
Catalog Number: 732-1924
UOM: 1 * 1 items
Supplier: HOEFER ELECTROPHORESIS


Description: The SE600 is ideal for all standard electrophoresis separations.
Catalog Number: 732-1918
UOM: 1 * 1 items
Supplier: HOEFER ELECTROPHORESIS


Description: The Owl™ P10DS dual gel system casts and runs one or two 20×20 cm gels in the upper buffer chamber. The larger size cassette allows the maximum number of samples and separation length. The system is ideal for second dimension protocols of 2-D electrophoresis applications.
Catalog Number: 730-0263
UOM: 1 * 1 items
Supplier: THERMO OWL SCIENTIFIC


1 409 - 1 424 of 56 536